SASO GSO IEC 60335-2-29 Household and similar electrical appliances – Safety – Part 2 – 29: Requirements for battery chargers.
IEC 60335-2-29
SASO IEC 62509 Battery charge controllers for photovoltaic systems – Performance and Operation.
IEC 62509
SASO IEC 62637-2 Battery charging interface for small handheld multimedia devices – Part 2: 2 mm barrel interface type conformity test
IEC 62637-2
SASO IEC 62680-1-1 Universal serial bus interfaces for data and power (USB) – Part 1-1: Common components – USB Power Delivery specification
IEC 62680-1-1
SASO IEC 62637-1 Battery charging interface for small handheld multimedia devices – Part 1: 2 mm barrel interface
IEC 62637-1
SASO IEC TR 61044 Charging Lead Acid Traction Batteries
IEC TR 61044
SASO 269 Dry primary batteries
SASO IEC 60086-1 Primary batteries – Part 1: General
IEC 60086-1
SASO IEC 60086-2 Primary batteries – Part 2: Physical and electrical specifications
IEC 60086-2
SASO IEC 60086-3 Primary batteries – Part 3: Watch batteries
IEC 60086-3
SASO IEC 60130-17 Connectors for frequencies below 3 MHz – Part 17: Detail specification for interconnection devices which permit multi-directional mating, for use with rechargeable batteries
IEC 60130-17
SASO-IEC 60622 Secondary cells and batteries containing alkaline or other non-acid electrolytes – Sealed nickel-cadmium prismatic rechargeable single cells

 

IEC 60622
IEC 60623 Secondary cells and batteries containing alkaline or other non-acid electrolytes – Vented nickel-cadmium prismatic rechargeable single cells
EN 60623
SASO ISO 13064-1 Electric battery for three-wheeled mopeds and motorcycles – Performance – Part 1: Reference consumed power and range

 

 

ISO 13064-1
SASO ISO13064-2 Electric battery for three-wheeled mopeds and motorcycles – Performance – Part 2: Road operating characteristics
ISO 13064-2
SASO IEC 60050-482 International Electro technical Vocabulary – Chapter 482: Primary and secondary cells
IEC 60050-482
SASO IEC 60086-5 Primary batteries – Part 5: Safety of batteries with aqueous electrolyte
IEC 60086-5
SASO IEC 60092-305 Electrical installations in ships – Part 300: Accumulator (storage) batteries
IEC 60092-305
SASO IEC 60952-1 Aircraft batteries – Part 1: General test requirements and performance levels
IEC 60952-1
SASO IEC 60952-2 Aircraft batteries – Part 2: Design and construction requirements
IEC 60952-2
SASO IEC 60952-3 Aircraft batteries – Part 3: External electrical connectors
IEC 60952-3
SASO 1919 Lead-acid starter batteries used for motor vehicles and internal combustion engines
SASO IEC 60095-4 Lead-acid starter batteries – part 4: dimensions of batteries for heavy vehicles
IEC 60095-4
SASO IEC 60254-2 Lead-acid traction batteries- Part 2: Dimensions of cells and terminals and marking of polarity on cells

 

IEC 60254-2
SASO IEC 60896-22 Stationary lead-acid batteries – Part 22: Valve regulated types – Requirements
IEC 60896-22
SASO IEC 61056-2 Portable lead acid cells and batteries (valve regulated types) Dimensions, terminals and markings
IEC 61056-2
SASO IEC 61434 Secondary cells and batteries containing alkaline or other non-acid electrolytes – Guide to designation of current in alkaline secondary cell and battery standards
IEC 61434
SASO IEC 61951-1 Secondary cells and batteries containing alkaline or other non-acid electrolytes – Secondary sealed cells and batteries for portable applications – Part 1: Nickel-Cadmium
IEC 61951-1
SASO IEC 61951-2 Secondary cells and batteries containing alkaline or other non-acid electrolytes – Secondary sealed cells and batteries for portable applications – Part 2: Nickel-metal hydride
IEC 61951-2
SASO IEC 62133-1 Secondary cells and batteries containing alkaline or other non-acid electrolytes – Safety requirements for portable sealed secondary cells, and for batteries made from them, for use in portable applications – Part 1: Nickel systems
IEC 62133-1
SASO IEC 62259 Secondary cells and batteries containing alkaline or other non-acid electrolytes – Nickel-cadmium prismatic secondary single cells with partial gas recombination
IEC 62259
SASO IEC 60086-4 Primary batteries – Part 4: Safety of lithium batteries
IEC 60086-4
SASO IEC 61960-3 Secondary cells and batteries containing alkaline or other non-acid electrolytes – Secondary lithium batteries and cells for use in portable applications – Part 3 – Lithium prismatic and cylindrical cells and batteries and batteries made from them
IEC 61960-3
SASO IEC 62133-2 Secondary cells and batteries containing alkaline or other non-acid electrolytes – Safety requirements for portable sealed secondary lithium cells, and for batteries made from them, for use in portable applications – Part 2: Lithium systems
IEC 62133-2
SASO IEC 62281 Safety of primary and secondary lithium cells and batteries during transport

 

IEC 62281
SASO IEC 62485-1 Safety requirements for secondary batteries and battery installations – Part 1: General safety information
IEC 62485-1
SASO IEC 62485-2 Safety requirements for secondary batteries and battery installations – Part 2: Stationary batteries
IEC 62485-2
SASO IEC 61429 Marking of secondary cells and batteries with the international recycling symbol ISO 7000-1135
IEC 61429
SASO IEC TR 61431 Guidelines for the use of monitor systems for lead-acid traction batteries
IEC TR 61431
SASO IEC TR 61438 Possible safety and health hazards in the use of alkaline secondary cells and batteries – Guide to equipment manufacturers and users
IEC TR 61438
SASO IEC TR 62060 Monitoring of lead acid stationary batteries and cells – User guide
IEC TR 62060
SASO IEC TR 62188 Secondary cells and batteries containing alkaline or other non-acid electrolytes – Design and manufacturing recommendations for portable batteries made from sealed secondary cells
IEC TR 62188
SASO IEC TS 62257-8-1 Recommendations for small renewable energy and hybrid systems for rural electrification – Part 8-1: Selection of batteries and battery management systems for stand-alone electrification systems – Specific case of self-propelled automotive flooded lead-acid batteries – Specific case of auto batteries
IEC TS 62257-8-1
SASO IEC 61427-2 Secondary cells and batteries for renewable energy storage – General requirements and methods of test – Part 2: Photovoltaic on-grid application.
IEC 61427-2
SASO IEC TS 62393 Portable and hand-held multimedia equipment – Mobile computers – Battery run-time measurement
IEC TS 62393
SASO IEC 61959 Secondary cells and batteries containing alkaline or other non-acid electrolytes – Mechanical tests for sealed portable secondary cells and batteries
IEC 61959
SASO IEC 61982 Secondary batteries (except lithium) for propulsion of electric road vehicles- Performance and endurance tests
IEC 61982
SASO 286 Terminals for dry primary batteries and their methods of test
SASO ISO 12819 Methods of evaluation of the battery life of a battery-powered watch
ISO 12819
SASO 1920 Lead-acid starter batteries used for motor cars – Road vehicles and internal combustion engines
SASO 268 Methods of test for dry primary batteries
SASO 795 Method of test for water for lead-acid batteries
SASO IEC 60896-11 Stationary lead–acid batteries – Part 11: Vented types – General Requirements – Methods of test
IEC 60896-11
SASO IEC 60896-21 Stationary lead–acid batteries – Part 21: valve-regulated types – General Requirements – Methods of test
IEC 60896-21
SASO IEC 61056-1 General purpose of lead-acid batteries (valve-regulated types) – Part 1: General Requirements, functional properties – Methods of test
IEC 61056-1
SASO IEC TS 61430 Secondary cells and batteries – Test methods for checking the performance of devices designed for reducing explosion hazards – Lead-acid starter batteries
IEC TS 61430

 

CONTACT US

""
1
Name
Message
0 /
Previous
Next

Address: Autostrada Durres - Tirane 2km, Durres, Albania

Phone: +355 68 464 2186

Email: info@alphatic.al